2
Wire Hydralic Hose
|
|
EN 853
2SN - SAE 100 R2AT
Tube:
|
Oil resistant synthetic
rubber
|
Reinforcement:
|
Two high tensile
steel braids
|
Cover:
|
Weather, oil, abrasion
and ozone resistant synthetic rubber
|
Application:
|
High pressure hydraulic
systems.
High pressure service with petroleum base hydraulic fluids,
waterglycol and water-fire resistant hydraulic fluids, hot
oil, grease, lubtricants, crude and fuel oils, air and water.
For air or gas application above 1.7 Mpa (250 PSI) the cover
should be pin pricked. MSHA or LOBA accepted cover on request.
|
PART
NUMBER
|
Hose
I.D.
|
Dash
|
Hose
O.D.
|
MAX
W.P.
|
MIN
B.P.
|
Min
Bend
Radius
|
Weight
|
mm
|
in
|
size
|
mm
|
in
|
MPa
|
psi
|
MPa
|
psi
|
in
|
mm
|
Kg/m
|
lb/C
ft
|
845AA00500HAA8
|
4,8
|
3/16
|
-3
|
13,4
|
0,53
|
42
|
6000
|
168
|
24000
|
3,6
|
90
|
0,3
|
20,1
|
845AA00600HAA8
|
6,4
|
1/4
|
-4
|
15
|
0,59
|
40
|
5800
|
160
|
23200
|
4
|
100
|
0,34
|
22,78
|
845AA00800HAA8
|
7,9
|
5/16
|
-5
|
16,7
|
0,66
|
35
|
5000
|
140
|
20000
|
4,6
|
115
|
0,43
|
28,81
|
845AA01000HAA8
|
9,5
|
3/8
|
-6
|
19,1
|
0,75
|
33
|
4800
|
132
|
19200
|
5
|
125
|
0,53
|
35,51
|
845AA01200HAA8
|
12,7
|
1/2
|
-8
|
22,2
|
0,87
|
28
|
4000
|
112
|
16000
|
7
|
175
|
0,65
|
43,55
|
845AA01600HAA8
|
15,9
|
5/8
|
-10
|
25,4
|
1,00
|
25
|
3630
|
100
|
14520
|
8
|
200
|
0,76
|
50,92
|
845AA01900HAA8
|
19
|
3/4
|
-12
|
29,3
|
1,15
|
21,5
|
3120
|
86
|
12480
|
9,6
|
240
|
0,92
|
61,64
|
845AA02500HAA8
|
25,4
|
1
|
-16
|
38,1
|
1,50
|
16,5
|
2400
|
66
|
9600
|
12
|
300
|
1,4
|
93,8
|
845AA03100HAA8
|
31,8
|
1.1/4
|
-20
|
48,3
|
1,90
|
12,5
|
1820
|
50
|
7280
|
16,8
|
420
|
1,9
|
127,3
|
845AA03800HAA8
|
38,1
|
1.1/2
|
-24
|
54,6
|
2,15
|
9
|
1310
|
36
|
5240
|
20
|
500
|
2,3
|
154,1
|
845AA05100HAA8
|
50,8
|
2
|
-32
|
67,4
|
2,65
|
8
|
1160
|
32
|
4640
|
25,2
|
630
|
2,95
|
197,65
|
Temperature
range: |
Constant
operation:
|
-40°C +100°C
|
Ambient
temperature:
|
-40°C +80°C
|
|
Length:
|
Random up to 1"
- 40 mt. max over 1"
|
Branding:
|
ALFAGOMMA FLEXOR
2AT/2SN ID...WP...MPa (...PSI) - SAE 100 R2AT - EN 853 2SN
DN... Q/yr
|
Note:
|
Max operating temperature
125°C
Air max 70°C
Operating temperature in excess of 100°C may materially
reduce the life of the hose
Hose cover does not need to be removed before attaching
couplings.
|
|